Residual Current Device testing and safety switch verification to protect your people.

RCD Testing

Overview

Safety Switch Verification & Compliance

An RCD (Residual Current Device) is a life-saving safety device that monitors the flow of electricity through a circuit. When it detects an imbalance — indicating current is leaking through a person o...

  • RCDs are the single most effective device for preventing electrocution — they can disconnect power in as little as 30 milliseconds, fast enough to save a life.
  • Under the Health and Safety at Work Act 2015, all New Zealand workplaces must have RCD protection for circuits supplying portable equipment. Regular testing is a legal requirement.
  • A faulty RCD that fails to trip provides zero protection while giving a false sense of security — the only way to confirm it works is through proper testing.
  • RCDs can degrade over time due to environmental factors, age, and electrical surges. Regular testing identifies devices that have become unreliable before they are needed in an emergency.

RCD Safety Switch

30mA residual current

T
<30ms

Push-Button Test

PASS

Operating Time

PASS

Non-Trip Test

PASS

Wiring Check

PASS

Why It Matters

Why RCD Testing matters

RCDs are the single most effective device for preventing electrocution — they can disconnect power in as little as 30 milliseconds, fast enough to save a life.

Under the Health and Safety at Work Act 2015, all New Zealand workplaces must have RCD protection for circuits supplying portable equipment. Regular testing is a legal requirement.

A faulty RCD that fails to trip provides zero protection while giving a false sense of security — the only way to confirm it works is through proper testing.

RCDs can degrade over time due to environmental factors, age, and electrical surges. Regular testing identifies devices that have become unreliable before they are needed in an emergency.

Common Issues

Common RCD Testing faults

Slow trip time

Risk

RCD disconnects too slowly to prevent electrocution — the person may receive a dangerous or fatal shock before the circuit is broken.

Action

RCD removed from service immediately and replaced with a compliant device.

Failure to trip

Risk

RCD provides zero protection against electrocution despite appearing functional — a potentially fatal condition.

Action

RCD removed from service immediately and replaced. Circuit de-energised until replacement is installed.

Nuisance tripping

Risk

RCD trips during normal operation, causing unnecessary power interruptions to equipment and work areas.

Action

RCD tested to determine if the device is defective or if there is a genuine earth leakage issue on the circuit.

Incorrect wiring

Risk

RCD may not detect earth leakage correctly, or may create a hazard by switching the wrong conductor.

Action

Wiring corrected by a qualified electrician and RCD retested before return to service.

Testing Frequency

How often should you test?

Environment
Frequency
Construction sites (push-button test)
Daily
Construction sites (operating time test)
Every 3 months
Factories and workshops
Every 6 months
Offices (push-button test)
Every 12 months
Offices (operating time test)
Every 2 years
AS/NZS 3760

Inspection & Testing Intervals

Recommended inspection and testing frequencies based on AS/NZS 3760 for different workplace environments and equipment types.

Caution

This information should be read together with the AS/NZS 3760 standard as a whole, particularly Clause 2.1. Inspection intervals vary depending on equipment type and operating environment.

1Factories, workshops, places of work or repair manufacturing, assembly, maintenance or fabrication

Tag: 6 months
RCD Push (P): Daily, or before every use, whichever is the longer
RCD Push (F): 6 months
RCD Time (P): 12 months
RCD Time (F): 12 months

2Environment where the equipment or supply flexible cord is subject to flexing in normal use OR is open to abuse OR is in a hostile environment

Tag: 12 months
RCD Push (P): 3 months
RCD Push (F): 6 months
RCD Time (P): 12 months
RCD Time (F): 12 months

3Environment where the equipment or supply cord is NOT subject to flexing in normal use and is NOT open to abuse and is NOT in a hostile environment

Tag: 5 years
RCD Push (P): 3 months
RCD Push (F): 6 months
RCD Time (P): 2 years
RCD Time (F): 2 years

4Residential type areas of hotels, residential institutions, motels, boarding houses, halls, hostels, accommodation houses, and the like

Tag: 2 years
RCD Push (P): 6 months
RCD Push (F): 6 months
RCD Time (P): 2 years
RCD Time (F): 2 years

5Equipment used for commercial cleaning

Tag: 6 months
RCD Push (P): Daily, or before every use, whichever is the longer
RCD Push (F): NA
RCD Time (P): 6 months
RCD Time (F): NA

6Hire Equipment

Inspection

Tag: Prior to hire
RCD Push (P): Including push-button test by hirer prior to hire
RCD Push (F): NA
RCD Time (P): NA
RCD Time (F): NA

Test and Tag

Tag: 3 months
RCD Push (P): NA
RCD Push (F): NA
RCD Time (P): 3 months
RCD Time (F): 12 months

7Repaired, serviced and second-hand equipment

After repair or service which could affect electrical safety, or on reintroduction to service, refer to AS/NZS 5762

Important Note

Inspection frequencies depend on equipment type, condition, and working environment. Hostile environments require more frequent inspection and testing. Always refer to AS/NZS 3760 or contact our team if you are unsure which interval applies to your workplace.

Our Process

How RCD Testing works

Our streamlined process ensures every rcd testing engagement is efficient, thorough, and fully documented.

Step 01

RCD Location & Identification

Our technician identifies all RCDs on site — switchboard-mounted RCBOs, portable RCDs used with power tools, and RCD-protected power outlets in kitchens, wet areas, and outdoor locations.

Step 02

Visual Inspection

Each RCD is visually inspected for physical damage, correct wiring, secure mounting, and switchboard condition. Any installation issues are noted.

Step 03

Push-Button Test

The built-in test button on each RCD is pressed to verify basic trip functionality. This confirms the RCD's internal circuitry is operational.

Step 04

Operating Time Test

A calibrated RCD tester injects a controlled fault current and measures the exact time taken for the RCD to disconnect. Results are compared against AS/NZS 3760 requirements.

Step 05

Results & Labelling

Pass or fail result determined based on trip time and functionality. Each RCD is labelled with test date, result, and next due date.

Step 06

Digital Reporting

Full RCD test report with trip times, test conditions, locations, and pass/fail status delivered to your online portal within 24 hours.

What's Tested

RCD Testing checklist

Push-Button Test

Verifies the RCD trips when the built-in test button is pressed, confirming basic functional operation.

Operating Time Test

Measures the exact time taken for the RCD to disconnect at rated residual current (e.g., 30mA) using a calibrated RCD tester.

Non-Trip Test

Tests at half-rated current to verify the RCD does not nuisance trip during normal operation, which would cause unnecessary power interruptions.

Wiring Condition

Visual inspection of RCD wiring, connections, mounting, and switchboard condition to identify any installation issues.

Label & Documentation

Each RCD is labelled with test date, result, trip time, and next test due date for easy identification.

Compliance Recording

All test results — including trip times, test conditions, and pass/fail status — recorded in your digital compliance report.

What You Receive

What you receive

RCD Test Report

Detailed report with exact trip times, test current levels, test conditions, and pass/fail status for every RCD tested across your site.

Compliance Certificate

Formal certificate confirming all RCDs have been tested in accordance with AS/NZS 3760, suitable for regulatory submissions and insurance purposes.

RCD Location Register

Complete register of all RCDs with locations, types (switchboard/portable/outlet), ratings, and full test history.

Online Portal Access

24/7 access to RCD test results, compliance status, and historical test data through your secure online portal.

Automated Reminders

Email alerts when RCDs are approaching their next test due date, ensuring continuous compliance.

Benefits

Why choose our rcd testing service

Life-Saving Protection

RCDs are the single most effective device for preventing electrocution. Regular testing ensures they work when needed.

Legal Compliance

RCD testing is required under WHS legislation and AS/NZS 3760 for all New Zealand workplaces.

Push-Button & Operating Time Tests

We perform both user-level push-button tests and precision operating time measurements with calibrated equipment.

Detailed Documentation

Every RCD test is recorded with trip times, test conditions, and pass/fail status in your compliance report.

Industries

Industries We Serve

Trusted across New Zealand's key industries

FAQ

RCD Testing FAQ

Ready to Get Started?

Get a fast, obligation-free quote from New Zealand's trusted Test & Tag specialists.